Sterilization and Decontamination Equipment
Vertical Autoclave
Digital top-loading steam sterilizer for compatible laboratory glassware, media, instruments, liquids and validated laboratory-waste applications.
Product Identity
1Product Name
ALC-SCIENTIFIC Digital Vertical Autoclave
Top-loading laboratory steam sterilizer for controlled sterilization and decontamination of compatible loads.
Classification
2Product Category
Product Overview
3Professional Product Overview
The ALC-SCIENTIFIC Digital Vertical Autoclave is a top-loading steam sterilizer designed for controlled sterilization and decontamination of compatible laboratory materials using saturated steam under pressure. It may be used for laboratory glassware, culture media, metal instruments, selected plastics, microbiological materials, liquid loads and laboratory waste when an appropriate validated cycle and load configuration are used. Depending on the selected configuration, the autoclave may include digital temperature and time control, programmable cycles, automatic air removal, controlled steam exhaust, liquid cooling, drying, load-temperature sensing, cycle recording and advanced safety interlocks. Vertical construction provides high chamber capacity within a comparatively compact floor area. Final chamber capacity, sterilization range, operating pressure, controller functions, utilities and compliance must be confirmed for the selected ALC-SCIENTIFIC model.
Functional Highlights
4Key Features
- Vertical top-loading chamber configuration.
- Saturated-steam sterilization under pressure.
- Digital or microprocessor-based process control.
- Reference sterilization range from approximately 105°C to 135°C or 140°C, model-dependent.
- Programmable sterilization temperature and holding time.
- Automatic heating, sterilization and exhaust sequence.
- Liquid, solid, glassware, media and waste cycle options in selected models.
- Stainless-steel sterilization chamber.
- Stainless-steel loading baskets or buckets.
- Automatic pressure and temperature monitoring.
- Safety interlock preventing opening under pressure.
- Low-water-level protection and overpressure safety valve.
- Audible and visual process alarms.
- Optional rapid cooling, vacuum drying and cycle documentation.
- Optional load-temperature sensor and biohazard exhaust filtration.
Technical Data
5Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Digital Vertical Autoclave |
| Sterilization Method | Saturated steam under pressure |
| Loading Direction | Vertical / top loading |
| ALC-SCIENTIFIC Model Number | To be confirmed |
| Chamber Capacity | To be confirmed |
| Reference Capacity Range | Approximately 20–160 litres |
| Chamber Shape | Cylindrical vertical chamber |
| Sterilization Temperature Range | To be confirmed |
| Reference Standard Range | Approximately 105°C to 135°C |
| Reference Advanced Range | Up to approximately 140°C |
| Temperature Setting Resolution | To be confirmed |
| Temperature Display Resolution | To be confirmed |
| Temperature Accuracy | To be confirmed |
| Temperature Uniformity | To be confirmed |
| Sterilization Time Range | To be confirmed |
| Reference Timer Range | 1 minute to extended programmable durations |
| Maximum Operating Pressure | To be confirmed |
| Reference Pressure Range | Approximately 0.18–0.20 MPa in selected configurations |
| Controller Type | Digital PID or microprocessor controller |
| Display | LED, LCD or colour touchscreen |
| Cycle Programs | Fixed or programmable, model-dependent |
| Program Memory | Model-dependent |
| Air Removal | Gravity displacement or vacuum-assisted |
| Steam Generation | In-chamber heater or separate steam generator |
| Temperature Sensor | Electronic chamber sensor |
| Load Temperature Sensor | Optional/model-dependent |
| Pressure Monitoring | Electronic and/or mechanical |
| Exhaust Control | Automatic, controlled or slow exhaust |
| Cooling | Natural cooling or optional rapid cooling |
| Drying | Optional vacuum or heat-assisted drying |
| Chamber Material | Stainless steel; grade to be confirmed |
| Reference Advanced Chamber Material | SS 316L or equivalent |
| External Body | Powder-coated steel or stainless steel |
| Loading Basket | Stainless-steel wire basket or solid bucket |
| Number of Baskets | Depends on chamber capacity |
| Door/Lid Type | Hinged top lid with locking mechanism |
| Door Interlock | Mechanical and/or electronic |
| Safety Valve | Provided; specification to be confirmed |
| Low-Water Protection | Model-dependent |
| Overtemperature Protection | Model-dependent |
| Overpressure Protection | Required |
| Alarm Functions | Temperature, pressure, water, door and cycle alarms |
| Cycle Printer | Optional |
| Data Logging | Optional/model-dependent |
| USB/SD/PC Interface | Optional/model-dependent |
| Drain Connection | Model-dependent |
| Water Supply | Manual filling or direct connection, model-dependent |
| Cooling Water | Required only for selected rapid-cooling systems |
| Compressed Air | Required only for selected advanced options |
| Exhaust Filtration | Optional for waste applications |
| Power Supply | To be confirmed |
| Reference Supply | 220–240 V AC, 50/60 Hz |
| High-Capacity Supply | Three-phase power may be required |
| Heater Power | To be confirmed |
| External Dimensions | To be confirmed |
| Net Weight | To be confirmed |
| Operating Environment | To be confirmed |
| Compliance | To be confirmed for the selected model |
| Warranty | To be confirmed |
Reference Capacity Classes
Vertical Autoclave Capacity Planning
| Reference Capacity | Reference Chamber Dimensions | Typical Configuration |
|---|---|---|
| 20–23 litres | Approximately Ø240–250 × 400–445 mm | Compact laboratory autoclave |
| 40 litres | Approximately Ø344 × 450 mm | Small vertical floor-standing autoclave |
| 55–62 litres | Approximately Ø344–380 × 490–600 mm | Routine microbiology and media preparation |
| 65–75 litres | Approximately Ø400 × 500–600 mm | Standard laboratory sterilization |
| 85 litres | Approximately Ø380–400 × 690–750 mm | General-purpose laboratory autoclave |
| 95–100 litres | Approximately Ø400–500 × 500–750 mm | Higher-volume laboratory processing |
| 120 litres | Approximately Ø500 × 600 mm | Large laboratory load capacity |
| 150–160 litres | Approximately Ø500 × 750 mm | High-capacity research and production support |
Reference Configurations
Compact, Standard and Advanced References
| Configuration | Reference Details |
|---|---|
| Compact Reference | Approximately 20–22 L; chamber around Ø240 × 445 mm; 105–123°C; approximately 0.18 MPa; 1.3 kW heater; 220 V single phase; approximately 60 kg. |
| Standard 85 L Reference | Approximately 85 L; chamber around Ø380 × 690 mm; vertical top loading; liquids, solids, glassware, instruments and suitable waste; optional accelerated cooling and drying. |
| Advanced Vertical Reference | Approximately 40–150 L; up to 140°C; up to approximately 4 bar absolute; up to 12 configurable programs; SS 316L reference chamber; optional rapid cooling, vacuum, drying and liquid-load monitoring. |
| Final ALC-SCIENTIFIC Values | To be confirmed |
Cycle Planning
Reference Sterilization Parameters
| Reference Cycle | Typical Temperature | Important Note |
|---|---|---|
| Gravity Steam Cycle | Approximately 121°C | Exposure time depends on load type and volume |
| Higher-Temperature Steam Cycle | Approximately 132–135°C | Only for compatible loads and validated cycles |
| Liquid Cycle | Commonly approximately 121°C | Requires slow exhaust and controlled cooling |
| Media Cycle | Application-dependent | Load-temperature sensing may be required |
| Waste Cycle | Application-dependent | Requires validated penetration and containment |
| Drying Cycle | Model-dependent | Used for suitable solid, wrapped or porous loads |
Laboratory Use
6Applications
Market Segments
7Industries Served
Steam Sterilization
8Working Principle
A Vertical Autoclave sterilizes compatible materials using saturated steam under controlled temperature and pressure. Water is heated to generate steam, air is removed from the chamber, and the controller raises the chamber to the programmed temperature and pressure. The holding period begins only after the required sterilization condition is reached. Steam is then exhausted in a controlled manner, followed by cooling and optional drying. Liquid loads require slower exhaust and cooling to reduce boiling, bottle breakage and loss of contents.
Gravity Displacement
Steam enters the chamber and displaces cooler air downward and outward. Suitable for many liquids, glassware and simple solid loads when properly validated.
Vacuum-Assisted Operation
Pre-vacuum removes air before steam admission and may improve penetration into porous, wrapped or complex loads. Availability is model-dependent.
Sterilizer Design
9Construction and Design
External Body
Powder-coated mild steel, stainless steel or combined construction. Final sheet thickness and finish are to be confirmed.
Sterilization Chamber
Cylindrical stainless-steel pressure chamber. Possible grades include SS 304, SS 316 and SS 316L.
Top-Loading Lid
May use hinged, wheel, lever or automatic locking with heat-resistant gasket and pressure/temperature-dependent interlocks.
Steam Generation
In-chamber immersion heater, integrated steam generator, external steam or jacket arrangement depending on configuration.
Loading System
Wire baskets, solid buckets, perforated baskets, flask racks, waste containers and lifting devices may be supplied.
Controller
May display chamber temperature, load temperature, pressure, time, cycle phase, water level, alarms and batch information.
Sensors
May include chamber, load, pressure, water-level, door-position, steam-generator and cooling-system sensors.
Exhaust and Drain
Automatic exhaust, slow liquid exhaust, condensate drain, exhaust cooling and optional biological filtration.
Operational Protection
10Safety and Compliance
- Lid or door interlock with pressure- and temperature-dependent locking.
- Cycle-start prevention when the lid is open or not correctly locked.
- Overpressure safety valve and low-water heater protection.
- Overtemperature cut-off and continuous pressure/temperature monitoring.
- Electrical leakage breaker and over-current protection.
- Sensor, heater, relay, water, pressure and cycle-failure alarms.
- Restricted opening until pressure and temperature are safe.
- Optional emergency stop and automatic fault diagnostics.
Range Planning
11Available Models or Variants
| Proposed Variant | Reference Capacity | Control Type | Key Difference | Recommended Application |
|---|---|---|---|---|
| Compact Vertical Autoclave | 20–23 litres | Digital or semi-automatic | Compact footprint | Teaching and small laboratories |
| Small Vertical Autoclave | 35–40 litres | Digital automatic | Routine processing | Media and glassware |
| Standard Vertical Autoclave | 50–60 litres | Digital automatic | General-purpose capacity | Microbiology and research |
| Medium Vertical Autoclave | 65–75 litres | Digital automatic | Increased basket capacity | Pharmaceutical and biotechnology laboratories |
| Large Vertical Autoclave | Approximately 85 litres | Digital automatic | Higher-volume liquid and solid loads | Central laboratory use |
| High-Capacity Vertical Autoclave | 100–120 litres | Advanced programmable | Multiple load programs | Research and pilot-scale work |
| Extra-Large Vertical Autoclave | 150–160 litres | Advanced programmable | Large-batch capacity | High-throughput laboratory sterilization |
| Vertical Autoclave with Drying | Model-dependent | Fully automatic | Vacuum or heat-assisted drying | Solid and porous loads |
| Vertical Autoclave for Liquids | Model-dependent | Fully automatic | Load sensor and controlled cooling | Culture media and solutions |
| Bio-Waste Vertical Autoclave | Model-dependent | Fully automatic | Exhaust filtration and waste cycle | Validated laboratory-waste treatment |
Final model codes, capacity, cycle functions and utility requirements: To be confirmed.
Configuration Options
12Optional Accessories
Accessory compatibility must be confirmed for the selected model.
Site Preparation
13Installation and Utility Requirements
| Requirement | Details |
|---|---|
| Electrical Supply | To be confirmed for selected capacity |
| Reference Supply | 220–240 V AC, 50/60 Hz |
| High-Capacity Supply | Three-phase supply may be required |
| Electrical Earthing | Required |
| Dedicated Circuit | Required or strongly recommended |
| Water Supply | Manual filling or direct connection, model-dependent |
| Feed-Water Quality | Must follow manufacturer requirements |
| Demineralized Water | May be required for selected steam generators |
| Cooling-Water Connection | Required for selected rapid-cooling systems |
| Drain Connection | Model-dependent |
| Drain Heat Resistance | Must tolerate hot condensate or include drain cooling |
| Compressed Air | Required only for selected advanced systems |
| External Steam | Required only for externally supplied configurations |
| Room Ventilation | Adequate heat and steam ventilation required |
| Installation Floor | Level, stable and load-bearing |
| Floor Loading | Must support autoclave, water and maximum load |
| Rear Clearance | Required for servicing and utilities |
| Side Clearance | Required for ventilation and access |
| Top Clearance | Required for complete lid opening |
| Doorway Clearance | Must be verified before delivery |
| Ceiling Height | Must allow lid and lifting-device operation |
| Ambient Temperature | To be confirmed |
| Relative Humidity | To be confirmed |
| Installation Altitude | To be confirmed |
| Pressure-Vessel Registration | Subject to local regulation |
| Initial Commissioning | Required |
| Calibration | Recommended before routine validated use |
| Cycle Validation | Required for critical applications |
| Operator Training | Required |
Lifecycle Support
14Maintenance and Support
- Clean the chamber after routine use and remove spills promptly.
- Use only compatible cleaning agents.
- Drain and replace chamber water according to the operating procedure.
- Inspect and clean the lid gasket and sealing surface regularly.
- Inspect safety valves according to the maintenance schedule.
- Check water-level protection and lid-locking functions.
- Keep drainage and exhaust lines free from obstruction.
- Inspect baskets and buckets for corrosion or damage.
- Descale heaters and chamber surfaces where required.
- Use specified feed-water quality.
- Calibrate temperature, pressure and timer functions.
- Test alarms and self-diagnostic systems.
- Replace biological exhaust filters according to the validated schedule.
- Inspect vacuum-pump oil and seals where applicable.
- Maintain cycle, calibration and maintenance records.
- Revalidate after major repair, relocation or controller modification.
Operational Benefits
15Product Advantages
Vertical Footprint
Provides high chamber capacity within a comparatively compact floor area.
Steam Sterilization
Saturated steam provides efficient heat transfer to compatible loads.
Cycle Flexibility
Liquid, media, solid, glassware and waste cycles may be configured according to model.
Safety Interlocks
Pressure, temperature and lid controls help restrict unsafe opening and operation.
Documentation Options
Printer, USB, SD-card and PC software options support cycle records and traceability.
OEM Configuration
Capacity, controls, cooling, drying and accessories can be configured for procurement needs.
Category Card Copy
16Website-Ready Short Description
The ALC-SCIENTIFIC Digital Vertical Autoclave provides saturated-steam sterilization for compatible laboratory glassware, media, instruments, liquids and waste. Available configurations may include digital microprocessor control, programmable cycles, stainless-steel chambers, safety interlocks, low-water protection, liquid-load sensing, rapid cooling, drying and cycle documentation.
Search Optimisation
17SEO Information
SEO Product Title
Vertical Autoclave for Laboratory | ALC-SCIENTIFIC
Meta Description
ALC-SCIENTIFIC vertical autoclave with digital steam sterilization control, stainless-steel chamber and multiple capacities for laboratory applications.
Primary Keyword
Vertical Autoclave
Suggested URL Slug
/products/autoclave/Suggested Image Path
/assets/feat-autoclave.jpgSuggested Image Alt Text
ALC-SCIENTIFIC Digital Vertical Autoclave
Secondary Keywords
Buyer Enquiry
18Technical Selection and Quotation Support
Contact ALC-SCIENTIFIC for selection and quotation according to required capacity, load type, sterilization temperature, cycle configuration, cooling, drying, documentation and utility requirements.
- Chamber-capacity selection
- Liquid or solid-load assessment
- Media-sterilization configuration
- Glassware and instrument cycles
- Laboratory-waste cycle selection
- Gravity or vacuum air-removal selection
- Liquid-load temperature sensing
- Controlled exhaust configuration
- Rapid-cooling options
- Vacuum-drying options
- Loading basket and bucket selection
- Exhaust-filtration options
- Water-supply planning
- Drain and cooling-water planning
- Power-supply assessment
- Printer and data-logging configuration
- PC and remote-monitoring options
- OEM customization
- Private labelling
- Commercial pricing
- Tender specifications
- Installation and commissioning
- Operator training
- Temperature and pressure calibration
- Cycle validation support
- IQ/OQ documentation
- Preventive maintenance
- Spare-part supply
- After-sales service