Biosafety and Clean-Air Equipment
Laminar Air Flow Cabinet
HEPA-filtered clean-air workstation for contamination-sensitive, non-hazardous laboratory work requiring product and process protection.
Product Identity
1Product Name
ALC-SCIENTIFIC Laminar Air Flow Cabinet – Horizontal/Vertical Clean Bench
Professional clean-air workstation for product and process protection during non-hazardous contamination-sensitive laboratory work.
Classification
2Product Category
Product Overview
3Professional Product Overview
The ALC-SCIENTIFIC Laminar Air Flow Cabinet is a clean-air workstation designed to protect non-hazardous products, samples and processes from airborne particulate contamination. Room air is drawn through a pre-filter and passed through a high-efficiency HEPA filter before entering the working chamber as uniform horizontal or vertical unidirectional airflow. The cabinet is suitable for clean assembly, media preparation, non-hazardous aseptic procedures, PCR reagent preparation, electronics work and other contamination-sensitive applications. Depending on the selected configuration, it may include airflow monitoring, digital controls, stainless-steel construction, UV lighting, electrical sockets and service ports. Final specifications must be confirmed for the selected ALC-SCIENTIFIC model.
Functional Highlights
4Key Features
- Horizontal or vertical laminar airflow configuration according to the application.
- HEPA-filtered unidirectional air supply for product and process protection.
- Reference H14 HEPA filtration efficiency of 99.995% at the most penetrating particle size.
- Pre-filter arrangement for removal of larger airborne particles before HEPA filtration.
- Reference airflow velocity of approximately 0.45 m/s in normal operating mode.
- Reduced airflow mode available in selected controller configurations.
- Stainless-steel or other cleanable working surface, model-dependent.
- Transparent side panels or front sash for visibility and access.
- Digital or microprocessor-based control panel, depending on configuration.
- Airflow-status indication and alarm functions in selected models.
- Energy-efficient brushless DC or EC blower option.
- Integrated work-area lighting with optional UV germicidal lamp.
Technical Data
5Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Laminar Air Flow Cabinet / Clean Bench |
| ALC-SCIENTIFIC Model Number | To be confirmed |
| Airflow Orientation | Horizontal or vertical |
| Primary Protection | Product and process protection |
| Personnel Protection | Not provided |
| Environmental Protection | Not provided |
| Work-Zone Cleanliness | Reference design: ISO Class 5 minimum; final validation required |
| Main Filter | HEPA filter |
| Reference Filter Classification | H14 HEPA, model-dependent |
| Reference Filter Efficiency | 99.995% at MPPS |
| Pre-Filter | Washable or replaceable pre-filter, model-dependent |
| Reference Air Velocity | Approximately 0.45 m/s |
| Reduced Air Velocity | Reference: approximately 0.23 m/s |
| Airflow Uniformity | To be confirmed through testing |
| Working Width | 3 ft, 4 ft, 5 ft or 6 ft reference configurations |
| Internal Chamber Material | Stainless steel or coated cleanable material |
| Work Surface | Stainless steel or other selected material |
| External Body | Powder-coated mild steel or stainless steel |
| Side Panels | Tempered safety glass or transparent acrylic, model-dependent |
| Front Access | Open front, sash or windscreen according to configuration |
| Controller | Digital or microprocessor-based |
| Display | LED, LCD or touchscreen, model-dependent |
| Airflow Monitoring | Model-dependent |
| Alarm System | Airflow and filter-status alarms, model-dependent |
| Blower Type | Brushless DC, EC or equivalent, model-dependent |
| Work-Area Lighting | LED or fluorescent, model-dependent |
| Reference Illumination | Up to or above 1000 lux in selected configurations |
| UV Lamp | Optional |
| Electrical Sockets | Model-dependent |
| Service Ports | Optional gas, vacuum, cable or utility ports |
| Noise Level | Reference: below 55–60 dB(A), configuration-dependent |
| Power Supply | To be confirmed |
| Power Consumption | Depends on cabinet size and blower configuration |
| Stand | Optional fixed or adjustable stand |
| Mobility | Optional lockable caster wheels |
| Operating Conditions | To be confirmed |
| Certification | To be confirmed for the selected model |
| Warranty | To be confirmed |
Reference Configurations
Reference Horizontal Clean-Bench Configurations
| Nominal Width | Internal Dimensions W × H × D | External Dimensions W × H × D | Reference Net Weight | Reference Power Consumption |
|---|---|---|---|---|
| 0.9 m / 3 ft | 920 × 645 × 585 mm | 1000 × 1170 × 810 mm | 110 kg | Up to 270 W |
| 1.2 m / 4 ft | 1220 × 645 × 585 mm | 1300 × 1170 × 810 mm | 125 kg | Up to 270 W |
| 1.5 m / 5 ft | 1520 × 645 × 585 mm | 1600 × 1170 × 810 mm | 140 kg | Up to 550 W |
| 1.8 m / 6 ft | 1820 × 645 × 585 mm | 1900 × 1170 × 810 mm | 160 kg | Up to 550 W |
| 1.8 m / 6 ft Extra Height | 1820 × 950 × 785 mm | 1900 × 1475 × 1010 mm | 170 kg | Up to 550 W |
Reference Performance
Performance Data for Engineering Verification
| Parameter | Reference Value |
|---|---|
| Normal Airflow Velocity | 0.45 m/s ±20% |
| Reduced Airflow Velocity | 0.23 m/s ±20% |
| Extra-Height Model Air Velocity | Approximately 0.40 m/s |
| HEPA Filter | H14 |
| Reference HEPA Efficiency | 99.995% at MPPS |
| Work-Zone Cleanliness | ISO Class 5 minimum reference condition |
| Work-Area Illumination | Greater than or equal to approximately 1000 lux |
| Reference Noise Level | Below approximately 55–60 dB(A) |
| Standard-Height Internal Depth | Approximately 585 mm |
| Electrical Receptacles | Up to three in selected reference configurations |
| Final ALC-SCIENTIFIC Values | To be confirmed |
Laboratory Use
6Applications
Market Segments
7Industries Served
Airflow Technology
8Working Principle
A Laminar Air Flow Cabinet creates a particle-controlled working environment by passing room air through filtration stages and supplying the cleaned air uniformly across the work surface. Room air is drawn into the cabinet by an internal blower. A pre-filter removes larger dust particles and helps reduce loading on the main HEPA filter. The air then passes through the HEPA filter and enters the work chamber as unidirectional airflow. This clean-air stream helps remove particles introduced by the surrounding room, equipment or operator.
Horizontal Airflow
In a horizontal clean bench, the HEPA filter is normally installed behind the work chamber. Filtered air travels from the rear of the cabinet toward the front opening and operator.
Vertical Airflow
In a vertical clean bench, the HEPA filter is normally positioned above the work chamber. Filtered air moves downward over the work surface and exits through the front opening or grille arrangement.
Cabinet Design
9Construction and Design
External Body
Powder-coated mild steel, stainless steel or combined construction. Material grade, sheet thickness and finish are to be confirmed.
Internal Working Chamber
May use SS 304, SS 316, powder-coated cleanable panels or tempered glass side walls according to configuration.
Work Surface
Stainless-steel work surface may be supplied for durability and routine cleaning. Removable or segmented tray design is model-dependent.
Filter System
May include intake pre-filter, H13/H14 HEPA filter, diffuser screen, supply plenum and filter-loading monitoring.
Blower Assembly
Brushless DC motor, EC motor, centrifugal blower or variable-speed airflow control can be offered according to the selected model.
Control Panel
May display blower status, airflow velocity, filter condition, operating hours, UV time, lighting status, socket status and service alarms.
Side Panels and Front Access
Transparent side panels improve visibility. Horizontal cabinets may have open fronts; vertical cabinets may include a sliding sash.
Stand and Mobility
Fixed stand, adjustable-height stand, levelling feet, lockable caster wheels or anti-tilt anchoring can be selected.
Use Limitation
10Safety and Compliance
Do Not Use For
Potentially infectious microorganisms, clinical specimens that may contain pathogens, hazardous drugs, toxic powders, sensitizing materials, volatile chemicals, radioactive materials or hazardous aerosol-generating work.
Select Instead
Use a Class II Biosafety Cabinet or another appropriate containment device when operator and environmental protection are required.
- Airflow monitoring and low-airflow alarm, model-dependent.
- Filter-loading indication and service reminders, model-dependent.
- Blower-interlock functions, UV timer and UV/lighting interlock where supplied.
- Over-current protection, electrical earthing and tempered safety-glass panels.
- Anti-tilt anchoring and lockable caster wheels where specified.
Range Planning
11Available Models or Variants
| Proposed Variant | Airflow Type | Reference Width | Key Difference | Recommended Application |
|---|---|---|---|---|
| Compact Horizontal Clean Bench | Horizontal | 3 ft | Compact working area | Small laboratory preparation and assembly |
| Standard Horizontal Clean Bench | Horizontal | 4 ft | General-purpose work zone | Media preparation and routine clean work |
| Large Horizontal Clean Bench | Horizontal | 5 ft | Increased working width | Larger equipment and multi-step procedures |
| Extended Horizontal Clean Bench | Horizontal | 6 ft | Wide work chamber | Production, packaging and assembly work |
| Compact Vertical Clean Bench | Vertical | 3 ft | Downward filtered airflow | Small instruments and PCR preparation |
| Standard Vertical Clean Bench | Vertical | 4 ft | General laboratory configuration | Research, clean assembly and sample preparation |
| Large Vertical Clean Bench | Vertical | 6 ft | Expanded work zone | High-volume or multi-equipment workflows |
Final ALC-SCIENTIFIC model codes, dimensions, airflow direction and controller options: To be confirmed.
Configuration Options
12Optional Accessories
Accessory compatibility must be confirmed for the selected model.
Site Preparation
13Installation and Utility Requirements
| Requirement | Details |
|---|---|
| Electrical Supply | To be confirmed according to the selected model |
| Reference Electrical Supply | 220–240 V AC, 50/60 Hz for common configurations |
| Electrical Earthing | Required |
| Dedicated Circuit | Recommended; rating to be confirmed |
| Water Connection | Normally not required |
| Gas Connection | Optional where a service valve is selected |
| Vacuum Connection | Optional |
| Drainage | Normally not required |
| External Exhaust | Not normally required for a recirculating clean bench |
| Floor or Bench | Stable, level and capable of supporting the cabinet |
| Stand | Fixed or adjustable, model-dependent |
| Rear Clearance | Required according to airflow intake and service design |
| Side Clearance | Required for service access and utility connections |
| Ceiling Clearance | Required for top air intake and filter servicing |
| Room Ventilation | Normal controlled laboratory ventilation |
| Airflow Disturbance | Install away from doors, windows, fans and air-conditioning outlets |
| Vibration | Install away from centrifuges, shakers and heavy moving machinery |
| Temperature | To be confirmed |
| Relative Humidity | To be confirmed |
| Installation Area | Cabinet dimensions plus operational and maintenance clearance |
| On-Site Testing | Recommended before routine operation |
Lifecycle Support
14Maintenance and Support
- Clean the internal working surface before and after use.
- Use only cleaning agents compatible with the work-surface and chamber materials.
- Remove spills promptly according to the facility procedure.
- Inspect and clean the intake pre-filter periodically.
- Replace the pre-filter when damaged or when airflow resistance increases.
- Do not puncture, wash or manually clean the HEPA filter.
- Monitor airflow status and alarm indications during operation.
- Inspect work-area lighting, sockets, service ports and sash components.
- Verify airflow velocity and uniformity periodically.
- Perform HEPA-filter integrity or leak testing after filter replacement.
- Conduct particle-count testing where cleanliness classification is claimed.
- Revalidate the cabinet after relocation, major repair or blower replacement.
- Inspect and replace UV lamps according to operating hours and measured performance.
- Keep maintenance, filter replacement and validation records.
Operational Benefits
15Product Advantages
Clean Work Zone
Provides a particle-controlled working area for contamination-sensitive non-hazardous processes.
HEPA-Filtered Airflow
Continuous filtered airflow helps protect products from surrounding airborne contamination.
Airflow Choices
Horizontal and vertical airflow options support different laboratory workflows and equipment layouts.
Size Flexibility
Multiple working widths allow selection according to process size, equipment footprint and available space.
Cleanable Construction
Stainless-steel work-area options simplify routine cleaning and laboratory maintenance.
OEM Configuration
Modular construction supports controller, material, size and accessory customization for procurement needs.
Category Card Copy
16Website-Ready Short Description
The ALC-SCIENTIFIC Laminar Air Flow Cabinet provides HEPA-filtered horizontal or vertical unidirectional airflow for contamination-sensitive, non-hazardous laboratory processes. Available configurations may include stainless-steel work areas, digital airflow monitoring, UV lighting, service ports and multiple working widths.
Search Optimisation
17SEO Information
SEO Product Title
Laminar Air Flow Cabinet | ALC-SCIENTIFIC
Meta Description
ALC-SCIENTIFIC laminar air flow cabinet with HEPA-filtered horizontal or vertical airflow for clean, non-hazardous laboratory applications.
Primary Keyword
Laminar Air Flow Cabinet
Suggested URL Slug
/products/laminar-flow/Suggested Image Path
/assets/feat-laminar-flow.jpgSuggested Image Alt Text
ALC-SCIENTIFIC Laminar Air Flow Cabinet
Secondary Keywords
Buyer Enquiry
18Technical Selection and Quotation Support
Contact ALC-SCIENTIFIC for selection and quotation according to required airflow orientation, working width, filter grade, construction material, controller type and application.
- Horizontal or vertical airflow selection
- Cabinet-size selection
- Application assessment
- HEPA-filter selection
- Stainless-steel construction options
- Controller and alarm selection
- Utility and service-port configuration
- OEM customization
- Private labelling
- Commercial pricing
- Tender specifications
- Site assessment
- Installation and commissioning
- Operator training
- Airflow testing
- HEPA-filter integrity testing
- Particle-count testing
- Preventive maintenance
- Filter replacement
- After-sales support
Related Products