ALC-Scientific Class II Type A2 Biosafety Cabinet

Biosafety and Clean-Air Equipment

Class II Type A2 Biosafety Cabinet

Designed for controlled handling of microbiological, diagnostic, cell-culture and research samples that may generate aerosols or droplets. The cabinet combines inward front airflow, filtered vertical downflow and filtered exhaust to support personnel, product and environmental protection.

Personnel protection Product protection Environmental protection 2 ft to 6 ft reference sizes

Professional Overview

Controlled containment for biological laboratory workflows.

The ALC-Scientific Class II Type A2 Biosafety Cabinet is intended for laboratories requiring controlled containment while handling biological materials. It is suitable for microbiology, clinical diagnostics, pharmaceutical quality control, biotechnology, cell culture and academic research. A typical Type A2 airflow system recirculates approximately 70% of filtered air and discharges approximately 30% through an exhaust filter. Depending on the finalized model, the cabinet may be configured with HEPA or ULPA filtration, a stainless-steel work zone, airflow monitoring, a manual or motorized sash and a microprocessor-based controller.

Class II Type A2 airflow configuration Approximately 70% filtered recirculation Approximately 30% filtered exhaust HEPA or ULPA filtration options SS 304 or SS 316 work chamber option Negative-pressure plenum arrangement Airflow and filter-life monitoring option Manual or motorized sash option Recessed stainless-steel work tray Lockable caster-mounted stand option

Technical Specifications

General configuration framework.

Final values must be confirmed against the selected ALC-Scientific model and approved manufacturing datasheet.

ParameterSpecification
Product typeBiological Safety Cabinet
ClassificationClass II, Type A2
ALC model numberTo be confirmed
Nominal working width2 ft, 3 ft, 4 ft or 6 ft reference configurations
Protection intentPersonnel, product and environmental protection
Airflow arrangementInward front airflow with vertical filtered downflow
Typical air recirculationApproximately 70%
Typical filtered exhaustApproximately 30%
Supply and exhaust filtersHEPA or ULPA, configuration-dependent
HEPA reference efficiency99.97% at 0.3 µm
ULPA reference efficiency99.9995% at 0.12 µm
Airflow velocityTo be confirmed
Interior constructionSS 304 or SS 316; selected grade to be confirmed
Exterior constructionPowder-coated mild steel
Work surfaceRemovable or single-piece recessed stainless-steel tray
Front sashManual or motorized, model-dependent
ControllerMicroprocessor-based controller; exact functions to be confirmed
DisplayLCD/keypad or touchscreen, model-dependent
Blower motorAC/DC-ECM option in applicable configurations
Reference noise level≤65 dB or <65 dB, depending on configuration
Internal lightingTo be confirmed
UV lampOptional/model-dependent; rating to be confirmed
Electrical socketsModel-dependent
Power supplyTo be confirmed
Power consumptionTo be confirmed
WeightTo be confirmed
Operating conditionsTo be confirmed
WarrantyTo be confirmed
Compliance statusTo be confirmed for each model

Reference Size Configurations

Engineering values requiring ALC model confirmation.

These are reference configurations derived from the supplied comparison source. Do not present them as finalized ALC-Scientific specifications until they are matched with approved ALC engineering drawings, airflow test data and model codes.
Working size Filter / controller Internal size External without stand External with stand Inflow Downflow Noise
2 × 2 × 2 ftULPA / Touchscreen605 × 500 × 540 mm705 × 650 × 1290 mm705 × 650 × 2220 mm290 m³/h360 m³/h≤65 dB
2 × 2 × 2 ftHEPA / LCD-Keypad610 × 610 × 610 mm774 × 764 × 1690 mm774 × 764 × 2400 mm240 m³/h442 m³/h<65 dB
3 × 2 × 2 ftULPA / Touchscreen910 × 600 × 660 mm1087 × 775 × 1458 mm1085 × 765 × 2220 mm445 m³/h649 m³/h≤65 dB
3 × 2 × 2 ftHEPA / LCD-Keypad910 × 610 × 610 mm1085 × 765 × 1690 mm1085 × 765 × 2400 mm445 m³/h649 m³/h<65 dB
4 × 2 × 2 ftULPA / Touchscreen1210 × 600 × 660 mm1383 × 775 × 1290 mm1383 × 775 × 2220 mm587 m³/h863 m³/h≤65 dB
4 × 2 × 2 ftHEPA / LCD-Keypad1220 × 610 × 610 mm1382 × 764 × 1690 mm1382 × 764 × 2400 mm595 m³/h884 m³/h<65 dB
6 × 2 × 2 ftULPA / Touchscreen1700 × 600 × 660 mm1873 × 775 × 1290 mm1873 × 775 × 2220 mm824 m³/h1212 m³/h≤65 dB
6 × 2 × 2 ftHEPA / LCD-Keypad1829 × 610 × 610 mm1991 × 764 × 1690 mm1995 × 764 × 2400 mm892 m³/h1325 m³/h<65 dB

Applications

Typical laboratory use cases.

Microbiological sample handling
Clinical specimen preparation
Cell and tissue culture procedures
Molecular biology sample preparation
Pharmaceutical microbiology and QC
Biotechnology research workflows
Food and environmental microbiology
Academic and institutional research

Industries Served

Designed for regulated and research-focused environments.

Pharmaceutical Biotechnology Healthcare Clinical Diagnostics Academic Research Government Laboratories Veterinary Diagnostics Food Microbiology Agricultural Research Environmental Testing

Working Principle

How the Type A2 airflow system operates.

Inward air barrier

Room air enters through the front access opening and is drawn into the front intake grille to reduce outward escape of cabinet air.

Filtered downflow

Filtered air moves vertically over the working zone to support controlled sample handling and reduce cross-contamination risk.

Internal recirculation

A typical Type A2 cabinet recirculates approximately 70% of filtered air through the internal airflow system.

Filtered exhaust

Approximately 30% passes through the exhaust filter before discharge to the room or an approved canopy connection.

Effective containment depends on correct installation, unobstructed grilles, appropriate work practices, validated airflow and periodic certification.

Construction and Design

Practical features for cleaning, monitoring and serviceability.

External body

Powder-coated mild-steel construction. Sheet thickness, coating process and final colour are to be confirmed for the selected ALC model.

Internal chamber

SS 304 or SS 316 working chamber option with a removable or recessed stainless-steel work tray for routine cleaning and minor spill containment.

Airflow plenum

Negative-pressure contaminated-air passages are intended to reduce the risk of unfiltered cabinet air escaping into the laboratory.

Front sash

Manual or motorized configurations may be offered. Sash-position monitoring and remote movement are model-dependent.

Control panel

LCD/keypad or touchscreen option. Functions may include airflow status, filter life, UV life, sash position, blower status and operating time.

Stand and mobility

Floor stand and lockable caster option for installation and controlled repositioning. Stand height and load rating are to be confirmed.

Safety and Compliance

Protection features and responsible application limits.

Potential safety provisions

  • Inward airflow at the front opening
  • Vertical filtered downflow
  • HEPA- or ULPA-filtered exhaust
  • Negative-pressure contaminated-air plenum
  • Airflow-status and filter-life monitoring options
  • Sash-position monitoring option
  • Recessed work tray for minor spill containment

Compliance statement

Compliance and certification details: To be confirmed based on the selected model.

Do not apply NSF/ANSI 49, CE or any other certification mark to an ALC-Scientific model unless the exact product is supported by valid certification documents and test records.

A standard recirculating Type A2 cabinet is not intended for routine handling of significant quantities of volatile toxic chemicals or radionuclides. Such work requires a documented risk assessment and may require an approved exhaust arrangement or another cabinet type.

Available Variants

Reference working-width selection.

VariantWorking widthKey differenceRecommended application
Compact2 ftReduced footprintLow-volume laboratories and restricted spaces
Compact Standard3 ftIncreased usable work zoneDiagnostic and academic laboratories
Standard Laboratory4 ftGeneral-purpose widthRoutine microbiology, cell culture and research
Large Working Area6 ftExpanded work surfaceHigher sample volume and multi-equipment workflows

Final ALC-Scientific model codes and available variants: To be confirmed.

Accessories and Utilities

Configuration options and installation requirements.

Technically relevant optional accessories

  • UV germicidal lamp
  • Motorized sash and remote-control unit
  • Adjustable floor stand with lockable casters
  • Canopy or thimble exhaust connection
  • External exhaust ducting kit
  • Additional electrical sockets
  • Gas or vacuum service tap
  • Replacement HEPA or ULPA filter
  • Voltage stabilizer or online UPS
  • Airflow testing and certification service

Installation and utility requirements

  • Electrical supply: To be confirmed
  • Electrical earthing: Required
  • Dedicated circuit: Recommended; rating to be confirmed
  • Water: Not normally required unless selected as a service
  • Gas/vacuum: Optional approved service connection
  • Floor: Level and capable of supporting the installed unit
  • Room location: Away from doors, strong drafts and disruptive air outlets
  • Operating conditions: To be confirmed
  • On-site certification: Required before routine use

Maintenance and Support

Routine practices supporting reliable containment.

Cleaning

Clean and disinfect the work surface, chamber and accessible area below the removable tray using materials compatible with the cabinet and laboratory procedure.

Airflow protection

Keep front and rear grilles free from instruments, paper and other obstructions. Avoid working practices that create rapid or disruptive air movement.

Inspection

Periodically inspect the sash, seals, service fixtures, electrical sockets, drain system and operating alarms according to the maintenance schedule.

Filter service

HEPA or ULPA filter replacement and internal repairs should be performed by qualified personnel following appropriate decontamination procedures.

Certification

Verify airflow and filter integrity at installation, periodically—commonly annually—and after relocation, airflow-related repairs or filter replacement.

ALC support scope

Installation, operator training, preventive maintenance, airflow testing, calibration coordination and replacement-part support are available subject to quotation.

Product Advantages

Practical operational benefits.

Combined personnel, product and environmental protection
Filtered vertical airflow for controlled biological work
Stainless-steel work area supports cleaning and decontamination
Negative-pressure passages improve containment design
Multiple working-width options for different laboratory footprints
Monitoring options simplify routine operational checks
Recessed tray supports minor spill management
Standard Type A2 operation generally avoids hard-connected exhaust

Frequently Asked Questions

Technical questions before model selection.

What protection does a Class II Type A2 biosafety cabinet provide?

When correctly installed, certified and operated, it is designed to support personnel, product and environmental protection using inward airflow, filtered downflow and filtered exhaust.

Which working width should be selected?

Selection depends on available laboratory space, sample volume, equipment placed inside the work zone and the workflow. Reference widths include 2 ft, 3 ft, 4 ft and 6 ft.

Can the cabinet be externally exhausted?

An approved canopy or thimble connection may be considered where required. The building exhaust arrangement must not interfere with cabinet airflow or containment.

Can volatile toxic chemicals be used inside it?

A standard recirculating Type A2 cabinet is not intended for routine use with significant quantities of volatile toxic chemicals or radionuclides. A formal risk assessment is required.

What information is needed for an accurate quotation?

Provide the working width, application, installation city, room and utility conditions, external exhaust requirement, required accessories and documentation or certification expectations.

Related Products

Complementary clean-air and sterilization equipment.

All Products

Technical Enquiry

Request model selection and commercial quotation.

Share your required size, application, quantity, delivery city, utility conditions and customization requirements. ALC-Scientific can assist with OEM configuration, installation, training, airflow testing, calibration coordination and after-sales support.

Product images are illustrative. Specifications, dimensions, airflow values, controller functions, accessories, certifications and warranty are subject to final model confirmation and the approved ALC-Scientific quotation.